Cad 2 Hour Fire Rated Wall Detail

Add a new project.
Cad 2 hour fire rated wall detail. 3 hour 1 1 2 hour. Dwelling unit and sleeping unit separations in buildings of type. Occupancies may be 2 hour fire walls in type iii and iv construction are. This is a 2 hour fire rated wall with wood structure.
2 hour fire wall assembly cad revit details. Search for cad details for your project needs. Maximum rating steel wood stud. Ss 503 control joints for fire rated systems.
A full cad set of details for tpo roofing. These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies. Elements of buildings the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated walls ceiling and floor assemblies. Search for cad details for your project needs.
3 hour 1 1 2 hour. Dwg pdf fire resistive interior wall joints comprehensive drawing 2 5 16 2 hr 2 hr top and bottom of wall joint for concrete over metal deck simplified drawing 2 29 16 2 hr 2 hr top and bottom of wall joint for flat deck simplified drawing 6 7 16 dwg pdf non fire rated smoke partition cp 506 smoke and acoustic sealant comprehensive. Wood stud wall systems double stud chase wall load bearing 1 hour rating ul u341 stc 57 has cad. Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
This is a similar to ul no 301 with stc 50min. The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels. This is the second and newest edition. 2 hour rating ul u388 stc 62 inslation one side stc 55 ral tl08 176 has cad.
Head of wall firestop system gypsum board fire trak shadowline. Ss 212 2 hour chase wall to steel deck. Ul design u465 v438. Details details details here it is all the roofing details you need for a typical tpo roofing project.
Knock down or welded welded. Head of wall firestop system elastomeric spray firestop. Head of wall firestop system proform quick set fs 90 compound 1 side ul design u411 v438. Ss 103 1 hour partition to steel deck.
Add to wish list. 2hour fire resistance rating by table 1020 1 2. Fire safety caution passing a fire test in a controlled laboratory setting and or certifying or labeling a product as having a one hour two hour or any other fire resistance or protection rating and therefore as acceptable for use in certain fire rated assemblies systems does not mean that either a particular assembly system incorporating the product or any given piece of the product.